APFC Panel has a microcontroller-based programmable controller which switches the capacitor banks of suitable capacity automatically in multiple stages by directly reading the reactive load (RKVA) which works in the principle of VAR sensing tends to maintain the PF to 0.99 Lag. The capacitor banks may be selected in a number of stages as 4/6/8 according to the load pattern. Modern power networks consist of a wide variety of electrical and power electronics loads, in case of such varying loads, the power factor also varies as a function of the load requirements. So it is practically difficult to maintain consistent power factor by the use of fixed compensation i.e. fixed capacitors which shall need to be manually switched to suit the variations of the load. It can lead to situations where the installation can have a low power factor leading to higher demand charges and levy of power factor penalties. In addition to not being able to achieve the desired power factor, it is also possible that the use of fixed compensation can also result in leading power factors under certain load conditions. This is also unhealthy for the installation as it can result in overvoltages, a saturation of transformers, maloperation of diesel generating sets, penalties by electricity supply authorities, etc. It is, therefore, necessary to automatically vary, without manual intervention, the compensation to suit the load requirements. This is achieved by using an Automatic Power Factor Correction (APFC) system which can ensure consistently high power factor without any manual intervention. In addition, the occurrence of leading power factors will be prevented.APFC products are fully automatic in operation and can be used to achieve, consistently high power factor under fluctuating load conditions Reduced KVA demand charges, Lower energy consumption in the installation by reducing losses Preventive leading power factor in an installation.

Install APFC Panel to avoid penalties and enjoy the benefits automatically. For maintaining the power factor according to the load factor, the proper capacity of capacitors is to be connected. The value of capacitors to be connected will vary with respect to load and its existing PF. There are two ways to maintain PF-
Fixing of the capacitor at the load end permanently or at the mains. Generally which is recommended for the fixed load like pumps, fans, etc. and it is not possible for the load which has variations in the load and PF.

The power factor can be maintained by installing Automatic Power Factor Control Panel (APFC Panel)

Reviews

There are no reviews yet.

Be the first to review “APFC”

Your email address will not be published. Required fields are marked *